• EI
  • Scopus
  • 食品科学与工程领域高质量科技期刊分级目录第一方阵T1
  • DOAJ
  • EBSCO
  • 北大核心期刊
  • 中国核心学术期刊RCCSE
  • JST China
  • FSTA
  • 中国精品科技期刊
  • 中国农林核心期刊
  • CA
  • WJCI
  • 中国科技核心期刊CSTPCD
  • 中国生物医学SinoMed
中国精品科技期刊2020
陈卫军,朱巧岚,汪海洋,等. 超声预处理对酪蛋白酸钠-EGCG相互作用及其复合物抗氧化活性的影响[J]. 食品工业科技,2024,45(21):30−36. doi: 10.13386/j.issn1002-0306.2023100201.
引用本文: 陈卫军,朱巧岚,汪海洋,等. 超声预处理对酪蛋白酸钠-EGCG相互作用及其复合物抗氧化活性的影响[J]. 食品工业科技,2024,45(21):30−36. doi: 10.13386/j.issn1002-0306.2023100201.
CHEN Weijun, ZHU Qiaolan, WANG Haiyang, et al. Effects of Ultrasound Pretreatment on Sodium Caseinate-EGCG Interactions and the Antioxidant Activity of Their Complexes[J]. Science and Technology of Food Industry, 2024, 45(21): 30−36. (in Chinese with English abstract). doi: 10.13386/j.issn1002-0306.2023100201.
Citation: CHEN Weijun, ZHU Qiaolan, WANG Haiyang, et al. Effects of Ultrasound Pretreatment on Sodium Caseinate-EGCG Interactions and the Antioxidant Activity of Their Complexes[J]. Science and Technology of Food Industry, 2024, 45(21): 30−36. (in Chinese with English abstract). doi: 10.13386/j.issn1002-0306.2023100201.

超声预处理对酪蛋白酸钠-EGCG相互作用及其复合物抗氧化活性的影响

Effects of Ultrasound Pretreatment on Sodium Caseinate-EGCG Interactions and the Antioxidant Activity of Their Complexes

  • 摘要: 采用荧光分光光度计、紫外分光光度计等研究了超声预处理对酪蛋白酸钠-表没食子儿茶素没食子酸酯((-)-epigallocatechin-3-gallate,EGCG)相互作用及其复合物抗氧化活性的影响,并从蛋白质结构变化上探究了其作用机理。结果表明:EGCG对酪蛋白酸钠内源荧光的淬灭形式为静态淬灭。超声预处理后酪蛋白酸钠同EGCG之间的结合常数由9.51×103 L·(mol/L)−1提高至7.48×104 L·(mol/L)−1,结合位点数由0.871提高至1.067,分别提高了7.87倍和22.50%,说明二者结合能力增强。同酪蛋白酸钠相比,超声预处理酪蛋白酸钠无规卷曲含量增加,内源荧光强度和表面疏水性指数增强,结构的改变促进了其同EGCG的结合。酪蛋白酸钠-EGCG复合物的形成可以抑制EGCG的降解、提高其抗氧化稳定性,而超声预处理能增强复合物的这一作用。

     

    Abstract: The interaction between sodium caseinate and (-)-epigallocatechin-3-gallate (EGCG) and the antioxidant activity of their complexes as influenced by ultrasound pretreatment were studied by a fluorescence spectrophotometer and an ultraviolet spectrophotometer, and its mechanism was also investigated base on the changes in protein structure. The results showed that the quenching of the endogenous fluorescence of sodium casein induced by EGCG was a static nature. With ultrasound pretreatment, the apparent binding constant between sodium caseinate and EGCG increased from 9.51×103 L·(mol/L)−1 to 7.48×104 L·(mol/L)−1 and the number of binding sites between sodium caseinate and EGCG increased from 0.871 to 1.067, indicating an increase of 7.87 times and 22.50%, respectively. The results revealed that ultrasound pretreatment could enhance the binding capacity of sodium caseinate for EGCG. Compared with sodium caseinate, ultrasound pretreated sodium caseinate showed higher random coil content, fluorescence intensity and surface hydrophobicity. These ultrasound-induced conformational changes promoted the binding between sodium casein and EGCG. Complexing with sodium caseinate could inhibit the degradation of EGCG and improve its antioxidant stability, and better protection was obtained by complexing EGCG with ultrasound pretreated sodium caseinate.

     

/

返回文章
返回