• EI
  • Scopus
  • 食品科学与工程领域高质量科技期刊分级目录第一方阵T1
  • DOAJ
  • EBSCO
  • 北大核心期刊
  • 中国核心学术期刊RCCSE
  • JST China
  • FSTA
  • 中国精品科技期刊
  • 中国农业核心期刊
  • CA
  • WJCI
  • 中国科技核心期刊CSTPCD
  • 中国生物医学SinoMed
中国精品科技期刊2020
杨金易, 张燕, 曾道平, 王弘, 徐振林, 沈玉栋, 雷红涛, 孙远明. 基于QuEChERS前处理技术的水产品中喹诺酮类药物多残留ELISA检测方法的建立[J]. 食品工业科技, 2015, (01): 292-298. DOI: 10.13386/j.issn1002-0306.2015.01.053
引用本文: 杨金易, 张燕, 曾道平, 王弘, 徐振林, 沈玉栋, 雷红涛, 孙远明. 基于QuEChERS前处理技术的水产品中喹诺酮类药物多残留ELISA检测方法的建立[J]. 食品工业科技, 2015, (01): 292-298. DOI: 10.13386/j.issn1002-0306.2015.01.053
YANG Jin- yi, ZHANG Yan, ZENG Dao-ping, WANG Hong, XU Zhen-lin, SHEN Yu- dong, LEI Hong-tao, SUN Yuan-ming. Simultaneous determination of Fluoroquinolones in seafood by modified Qu ECh ERS and Enzyme- linked Immunosorbent Assay[J]. Science and Technology of Food Industry, 2015, (01): 292-298. DOI: 10.13386/j.issn1002-0306.2015.01.053
Citation: YANG Jin- yi, ZHANG Yan, ZENG Dao-ping, WANG Hong, XU Zhen-lin, SHEN Yu- dong, LEI Hong-tao, SUN Yuan-ming. Simultaneous determination of Fluoroquinolones in seafood by modified Qu ECh ERS and Enzyme- linked Immunosorbent Assay[J]. Science and Technology of Food Industry, 2015, (01): 292-298. DOI: 10.13386/j.issn1002-0306.2015.01.053

基于QuEChERS前处理技术的水产品中喹诺酮类药物多残留ELISA检测方法的建立

Simultaneous determination of Fluoroquinolones in seafood by modified Qu ECh ERS and Enzyme- linked Immunosorbent Assay

  • 摘要: 建立了水产品中3种喹诺酮类(恩诺沙星、环丙沙星、氧氟沙星)兽药多残留的新型Qu ECh ERS前处理技术结合酶联免疫快速检测的分析方法。基本流程为样品经90%乙腈(1%乙酸)均质提取离心后,上清液依次用C18净化、静置沉淀蛋白后用于测定,该前处理方法灵敏、快速、经济、实用性强。测试曲线线性范围为0.107~177.896ng/m L,检出限为0.0087μg/kg,IC50值为4.34ng/m L。样品批内和批间平均回收率分别为94.10%、93.70%,批内变异系数为4.09%~8.41%,批间变异系数2.78%~7.99%。检测结果与HPLC的相关系数R2=0.9897,表明酶联免疫检测方法及样品前处理方法适合喹诺酮类药物多残留检测。 

     

    Abstract: A method was developed for the simultaneous determination of 3 Fluoroquinolones( FQs)( enrofloxacin,ciprofloxacin,ofloxacin) residues including enrofloxacin,ciprofloxacin,ofloxacin in seafood samples by new Qu ECh ERS and Enzyme- linked Immunosorbent Assay( ELISA). The approach involved the extraction of sample with acetonitrile containing 1%( v / v) acetic acid,and the supernatant liquid was directly purified with C18,meanwhile,was used for the precipitation of protein. The method was proved to be sensitive,rapid,precise,economical and applied. The calibration curve should be virtually linear in the range of 0.107 ~ 177.896 ng / m L,the limit of detection( LOD) was 0.0087μg / kg,and IC50 value was 4.34 ng / m L. Average recovery rate was 94.10% and93.70% separately in same batch and different batch,coefficient of variation was 4.09% ~8.41% and 2.78% ~7.99%separately in same batch and different batch.The results showed good coefficient with HPLC( R2= 0.9897),which proved to be suitable for the screening of seafood samples for the presence of FQs.

     

/

返回文章
返回