Determination of Sodium Chloride Content in High Salt Food by ICP-AES with Sub-sensitive Wave Line
-
摘要: 本文以高盐食品为研究对象,建立了运用等离子体发射光谱法(ICP-AES)次灵敏线(330.232 nm)检测高盐食品中NaCl含量的方法,并比较了外界共存离子以及不同前处理方法对于测定结果的影响。结果显示:ICP-AES次灵敏线(330.232 nm)的线性范围(10~300 mg/L,r=0.9995)宽于主灵敏线(589.59 nm)的线性范围(0~20 mg/L,r=0.9998)且精密度良好(RSD < 1.0%),可以规避传统方法测定样品因稀释梯度大而导致的误差;外界共存元素K、Ca、Mg、Sn及Zn离子对于ICP-AES发射光谱次灵敏线测定NaCl含量的结果没有影响,这也规避了滴定法中非目标氯化物带来的干扰;通过与国标方法的比较,ICP-AES发射光谱次灵敏线法的准确性与精密度均与国标法持平,这表明ICP-AES发射光谱次灵敏线在高盐食品中检测氯化钠含量的具有独特优势,具有一定的推广价值。
-
关键词:
- 次灵敏线 /
- 电感耦合等离子体发射光谱法 /
- 高盐食品 /
- NaCl
Abstract: A method for the determination of sodium chloride in high salt food by icp-atomic (ICP-AES) emission spectrometry with sub-sensitive wave line (330.232 nm) was established.And the effect of exogenous potassium ion, calcium ion, magnesium ion, tin ion and zinc ion on the determination of sodium chloride by ICP-AES emission spectrometry with sub-sensitive wave line was estimated.Moreover, the pretreatment was also optimized. The results illustrated that liner range of this method was wider (10~300 mg/L, r=0.9995) than the national standard method (0~20 mg/L, r=0.9998) and the precision was good (RSD < 1.0%), which was equal to the national standard method.The determination of sodium chloride by the ICP-AES emission spectrometry with sub-sensitive wave line method was not affected by the exogenous positive ions, which could avoid the bias from non-target chloride.The method was sensitive, accurate and could be applied in the determination of sodium chloride in high salt food.-
Keywords:
- sub-sensitive wave line /
- ICP /
- high salt food /
- NaCl
-
期刊类型引用(6)
1. 李小芳,张嘉,刘丽强,李丁,匡华,胥传来,郭玲玲. LC-MS/MS和GICA检测小麦中呕吐毒素质量分数及分布规律. 食品与生物技术学报. 2024(11): 90-97 . 百度学术
2. 甄思慧,李磊,王真. 免疫层析技术在食源性细菌检测中的应用及优化. 黑龙江畜牧兽医. 2022(23): 38-41 . 百度学术
3. 陈瑞鹏,高志贤,梁俊. 农产品中真菌毒素检测方法研究进展. 食品安全质量检测学报. 2021(06): 2283-2291 . 百度学术
4. 张海涛,祁苏娴,董曼佳,陆廷瑾,杨婷婷. 时间分辨荧光免疫层析法定量检测稻谷中的镉. 中国粮油学报. 2021(11): 170-173 . 百度学术
5. 周文颖,彭洒洒,牛子仑,沈子慧,张惠琴,史巧巧. 谷物中呕吐毒素免疫学检测方法的研究进展. 现代面粉工业. 2020(05): 26-29 . 百度学术
6. 李慧琴,易云婷,彭程. 纳米标记免疫层析技术在食品快速检测中的应用进展. 食品安全导刊. 2019(15): 160-162 . 百度学术
其他类型引用(8)
计量
- 文章访问数: 385
- HTML全文浏览量: 109
- PDF下载量: 43
- 被引次数: 14