Determination of heavy metal elements in food antcaking agent sodium aluminosilicate by inductively coupled plasma mass spectrometry
-
摘要: 以氢氟酸和硝酸为混合试剂采用密闭微波消解系统消解食品抗结剂硅铝酸钠样品,建立电感耦合等离子体质谱(ICP-MS)法测定硅铝酸钠中Cr、Ni、As、Cd、Sn、Sb、Hg、Pb等8种重金属元素的分析方法。研究了高盐基体存在时所产生的多原子离子质谱干扰,选择CH4为反应气,应用动态反应池(DRC)技术校正分析过程中的质谱干扰,采用基体匹配法并选择Rh为内标元素校正基体效应及元素分析信号的漂移。分析结果表明,该方法测定硅铝酸钠中8种重金属元素的检出限为1.8512.31ng/L,相对标准偏差在2.09%5.56%之间,样品的加标回收率为93.19%108.47%。国家标准(GBW07423)参考物质的分析结果与所提供的参考值基本一致。方法简单、快速、准确,可用于食品抗结剂硅铝酸钠的质量控制和安全评价。
-
关键词:
- 硅铝酸钠 /
- 电感耦合等离子体质谱 /
- 重金属元素 /
- 动态反应池 /
- 基体效应
Abstract: A method for simultaneous and quantitative determination of Cr, Ni, As, Cd, Sn, Sb, Hg and Pb in food antcaking agent sodium aluminosilicate by inductively coupled plasma mass spectrometry ( ICP- MS) was established. The samples were dissolved by using the mixture of HNO3+HF in a closed-vessel microwave digestion system, and then the 8 heavy metals elements in the digestion solution were analyzed directly by ICP- MS. The polyatomic ion interferences of mass spectrometry caused by the high salt substrate were investigated. The CH4 were used as reactant gas, and the dynamic reaction cell (DRC) could eliminate the mass spectral interferences raised in analytical process. The matrix maching and Rh as internal standard element were used to corrected matrix effect and signal drift to correct the matrix effect and signal drift. The results showed that the detection limits of the 8 heavy metals elements were in the range of 1.85 12.31ng/L, relative standard deviations were in the range of 2.09%5.56%, and the recoveries of standard addition were in the ranges of 93.19%108.47%, respectively. The results of reference standard materials (GBW07423) were in good agreement with the certified value. The method was simple, rapid, accurate and reliable, and could be used in food antcaking agent sodium aluminosilicate quality control and safety estimations. -
[1] GB 25583-2010, 食品安全国家标准食品添加剂硅铝酸钠[S]. [2] Houk R S, Fassel V A, Flesh G D, et al.Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elements[J].Analytical Chemistry, 1980, 52 (14) :2283-2289.
[3] 洪波, 王冬武, 伍远安, 等.微波消解-电感耦合等离子体质谱法测定背瘤丽蚌和鳙鱼体内8种微量元素[J].现代食品科技, 2013, 29 (5) :1163-1165. [4] Verboket P E, Borovinskaya O, Meyer N, et al.A new microfluidics-based droplet dispenser for ICPMS[J].Analytical Chemistry, 2014, 86 (12) :6012-6018.
[5] Nookabkaew S, Rangkadilok N, Mahidol C, et al.Determination of arsenic species in rice from thailand and other asian countries using simple extraction and HPLC-ICP-MS analysis[J].Journal of Agricultural and Food Chemistry, 2013, 61 (28) :6991-6998.
[6] Sanz-Medel A, Montes-Bayon M, Bettmer J, et al.ICP-MS for absolute quantification of proteins for heteroatom-tagged, targeted proteomics[J].Trends in Analytical Chemistry, 2012, 40:52-63.
[7] 刘虎生, 邵宏翔.电感耦合等离子体质谱技术与应用[M].北京:化学工业出版社, 2005:1-3. [8] Nardi E P, Evangelista F S, Tormen L, et al.The use of inductively coupled plasma mass spectrometry (ICP-MS) for the determination of toxic and essential elements in different types of food samples[J].Food Chemistry, 2009, 112 (3) :727-732.
[9] 王小如.电感耦合等离子体质谱应用实例[M].北京:化学工业出版社, 2005:266-267. [10] Nie Xidu, Fu Liang.Simultaneous determination of trace elements in hepatocellular carcinoma tissue by sector field inductively coupled plasma mass spectrometry[J].Analytical Letter, 2013, 46 (3) :488-497.
[11] Wu D, Pichler T.Simultaneous speciation analysis of As, Sb and Se redox couples by SF-ICP-MS coupled to HPLC[J].Analytical Methods, 2014, 6 (14) :5112-5119.
[12] Fu Liang, Nie Xidu, Xie Hualin, et al.Rapid multi-element analysis of Chinese vinegar by sector field inductively coupled plasma mass spectrometry[J].European Food Research and Technology, 2013, 237:795-800.
[13] Popp M, Hann S, Mentler A, et al.Determination of glyphosateand AMPA in surface and waste water using high-performance ion chromatography coupled to inductively coupled plasma dynamic reaction cell mass spectrometry (HPIC-ICP-DRC-MS) [J].Analytical Bioanalytical Chemistry, 2008, 391 (2) :695-699.
[14] Guo W, Hu S H, Xiao Y F, et al.Direct determination of trace cadmium in environmental samples by dynamic reaction cell inductively coupled plasma mass spectrometry[J].Chemosphere, 2010, 81 (11) :1463-1468.
[15] Pereira C D, Garcia E E, Silva F V, et al.Behaviour of arsenic and selenium in an ICP-QMS with collision and reaction interface[J].Journal of Analytical Atomic Spectrometry, 2010, 25 (11) :1763-1768.
计量
- 文章访问数:
- HTML全文浏览量:
- PDF下载量: