XIE Shuang, GAO Yu-sheng, LI Miao, SUN Lei-li, MU Yan, LI Yan, GAO Qun, YIN Da-lu. Study on determination of chromium in medicianl hollow capsules[J]. Science and Technology of Food Industry, 2014, (22): 81-83. DOI: 10.13386/j.issn1002-0306.2014.22.009
Citation: XIE Shuang, GAO Yu-sheng, LI Miao, SUN Lei-li, MU Yan, LI Yan, GAO Qun, YIN Da-lu. Study on determination of chromium in medicianl hollow capsules[J]. Science and Technology of Food Industry, 2014, (22): 81-83. DOI: 10.13386/j.issn1002-0306.2014.22.009

Study on determination of chromium in medicianl hollow capsules

  • The methods of GFAAS and ICP- MS for determination of Cr in medicinal hollow capsules were established. The samples were digested by microwave digestion comparing the two methods at the same time.The recoveries varied from 96.4% to 105.6%, and the relative standard deviations were less than 5.7%.The correlation coefficients for the standard curves of the two methods were greater than 0.999 with the detection limits of 0.083μg·L-1and 0.030μg·L-1respectively. The ICP-MS method was more simple and practical with time saving and high efficiency.