张申平,侯超,张妮,等. UPLC-Q/Orbitrap HRMS测定口服液中6种西地那非衍生物的不确定度分析[J]. 食品工业科技,2023,44(11):280−286. doi: 10.13386/j.issn1002-0306.2022060278.
引用本文: 张申平,侯超,张妮,等. UPLC-Q/Orbitrap HRMS测定口服液中6种西地那非衍生物的不确定度分析[J]. 食品工业科技,2023,44(11):280−286. doi: 10.13386/j.issn1002-0306.2022060278.
ZHANG Shenping, HOU Chao, ZHANG Ni, et al. Uncertainty Evaluation for Determination of 6 Sildenafil Derivatives in Oral Liquid by UPLC-Q/Orbitrap HRMS[J]. Science and Technology of Food Industry, 2023, 44(11): 280−286. (in Chinese with English abstract). doi: 10.13386/j.issn1002-0306.2022060278.
Citation: ZHANG Shenping, HOU Chao, ZHANG Ni, et al. Uncertainty Evaluation for Determination of 6 Sildenafil Derivatives in Oral Liquid by UPLC-Q/Orbitrap HRMS[J]. Science and Technology of Food Industry, 2023, 44(11): 280−286. (in Chinese with English abstract). doi: 10.13386/j.issn1002-0306.2022060278.

UPLC-Q/Orbitrap HRMS测定口服液中6种西地那非衍生物的不确定度分析

Uncertainty Evaluation for Determination of 6 Sildenafil Derivatives in Oral Liquid by UPLC-Q/Orbitrap HRMS

  • 摘要: 为了保证高分辨质谱法测定壮阳类口服液中西地那非类似物的结果准确性和可靠性,对测定结果进行不确定度评定是十分必要的。本研究采用超高效液相色谱-四极杆/静电场轨道阱高分辨质谱法(UPLC-Q/Orbitrap HRMS)测定口服液保健食品中6种西地那非衍生物的含量,依据JJF 1059.1-2012《测量不确定度评定与表示》,建立数学模型,进行测量不确定度评定。当口服液中N-去甲基西地那非、去甲基硫代西地那非、二甲基西地那非、羟基硫代豪莫西地那非、硫代豪莫西地那非、硫代西地那非的含量为0.90、1.04、1.22、2.01、1.51、1.14 mg/kg时,扩展不确定度分别为0.07、0.09、0.10、0.16、0.13、0.09 mg/kg(k=2)。评定结果表明,不确定度主要来自UPLC-Q/Orbitrap HRMS仪器、标准溶液配制、回收率和随机效应。

     

    Abstract: In order to ensure the accuracy and reliability of high resolution mass spectrometry for the determination of sildenafil derivatives in aphrodisiac oral liquid, it is necessary to evaluate the uncertainty of the determination results. In this study, the content of 6 sildenafil derivatives in oral liquid health food was determined by ultra-high performance liquid chromatography with quadrupole/electrostatic field Orbitrap high resolution mass spectrometry (UPLC-Q/Orbitrap HRMS). The mathematical model was established and the measurement uncertainty was evaluated according to JJF 1059.1-2012 “Evaluation and Expression of Measurement Uncertainty”. When the contents of N-demethyl sildenafil, dimethyl thiosildenafil, dimethyl sildenafil, hydroxythiocarmo sildenafil, thiocarmo sildenafil and thiosildenafil in oral solution were 0.90, 1.04, 1.22, 2.01, 1.51 and 1.14 mg/kg, the extended uncertainties were 0.07, 0.09, 0.10, 0.16, 0.13 and 0.09 mg/kg (k=2), respectively. The results show that the uncertainty mainly comes from UPLC-Q/Orbitrap HRMS, standard solution preparation, recovery and random effect.

     

/