• EI
  • Scopus
  • 食品科学与工程领域高质量科技期刊分级目录第一方阵T1
  • DOAJ
  • EBSCO
  • 北大核心期刊
  • 中国核心学术期刊RCCSE
  • JST China
  • FSTA
  • 中国精品科技期刊
  • 中国农业核心期刊
  • CA
  • WJCI
  • 中国科技核心期刊CSTPCD
  • 中国生物医学SinoMed
中国精品科技期刊2020
王兴华, 刘菊, 谢玉韬, 宋佳, 张帆, 乔沈. HPLC法检测生物硒醋及老陈醋乳酸和醋酸含量[J]. 食品工业科技, 2017, (16): 247-252. DOI: 10.13386/j.issn1002-0306.2017.16.047
引用本文: 王兴华, 刘菊, 谢玉韬, 宋佳, 张帆, 乔沈. HPLC法检测生物硒醋及老陈醋乳酸和醋酸含量[J]. 食品工业科技, 2017, (16): 247-252. DOI: 10.13386/j.issn1002-0306.2017.16.047
WANG Xing-hua, LIU Ju, XIE Yu-tao, SONG Jia, ZHANG Fan, QIAO Shen. Determination of lactic acid and acetic acid content in biological selenium vinegar and vinegar by HPLC method[J]. Science and Technology of Food Industry, 2017, (16): 247-252. DOI: 10.13386/j.issn1002-0306.2017.16.047
Citation: WANG Xing-hua, LIU Ju, XIE Yu-tao, SONG Jia, ZHANG Fan, QIAO Shen. Determination of lactic acid and acetic acid content in biological selenium vinegar and vinegar by HPLC method[J]. Science and Technology of Food Industry, 2017, (16): 247-252. DOI: 10.13386/j.issn1002-0306.2017.16.047

HPLC法检测生物硒醋及老陈醋乳酸和醋酸含量

Determination of lactic acid and acetic acid content in biological selenium vinegar and vinegar by HPLC method

  • 摘要: 本文研究了利用HPLC法测定生物硒醋和老陈醋中乳酸和醋酸的含量,并对其测定条件进行优化。应用以C18为色谱分析柱,检测波长为215 nm,流动相为2.5%NH4H2PO4缓冲液,样品稀释度为30倍,流速为1.0 min/m L,柱温为29℃,生物硒醋样品的最佳p H=2.5,老陈醋的最佳p H为2.7时,可以较好的分离、检测生物硒醋和老陈醋中乳酸和醋酸的含量,所有的检测在4 min内完成。同时当其他分析条件一定,p H=2.7时,醋酸和乳酸标样的回归方程分别为y=484.23x-81.373,R2=0.9992、y=441.37x-68.321,R2=0.9979。当p H=2.5时,醋酸和乳酸标样的回归方程分别为y=484.61x+72.201,R2=0.9993、y=389.82x+30.432,R2=0.9991。该检测方法重复性、准确度、精确度的相对标准偏差范围为0.00%1.07%,其中生物硒醋乳酸和醋酸标品的加标回收率分别为100.00%110.00%、99.00%100.83%,老陈醋乳酸和醋酸标品的加标回收率分别为100.00%101.00%、100.00%110.00%。此方法重复性好、准确性和精确性好,检测时间短。可以应用于生物硒醋和老陈醋的HPLC法有机酸的定量分析。 

     

    Abstract: Determination of lactic acid and acetic acid of biological selenium vinegar and vinegar by using HPLC method were studied.C18 as chromatographic analysis column, detection wavelength was 215 nm, the mobile phase was 2.5% NH4H2PO4 buffer, sample dilution was 30 times, the flow rate was 1.0 min/m L, the column temperature was 29 ℃, the best p H of the biological selenium vinegar was 2.5, while the best p H of the vinegar was 2.7, which could better separation and determination of lactic acid and acetic acid of biological selenium vinegar and vinegar, all testing completed within 4 min.When other analysis conditions were certain, p H was 2.5, the regression equation of acetic acid and lactic acid standard were y = 484.23x-81.373, R2= 0.9992, y = 441.37x-68.321, R2= 0.9979, respectively.When p H was 2.5, the regression equations of acetic acid and lactic acid standard were y = 484.61 x + 72.201, R2= 0.9993, y = 389.82 x + 30.432, R2= 0.9991, respectively. The relative standard deviation of this method was 0.00% 1.07%, standard addition recoveries of biological selenium vinegar lactic acid and acetic acid standard were 100.00% 110.00%, 99.00% 100.83% respectively, standard addition recoveries of vinegar lactic acid and acetic acid were 100.00% ~ 101.00%, 100.00% ~ 110.00% respectively. The method has good repeatability, accuracy and precision, short detection time, therefore it could be applied in biological selenium vinegar and vinegar.

     

/

返回文章
返回