• EI
  • Scopus
  • 食品科学与工程领域高质量科技期刊分级目录第一方阵T1
  • DOAJ
  • EBSCO
  • 北大核心期刊
  • 中国核心学术期刊RCCSE
  • JST China
  • FSTA
  • 中国精品科技期刊
  • 中国农业核心期刊
  • CA
  • WJCI
  • 中国科技核心期刊CSTPCD
  • 中国生物医学SinoMed
中国精品科技期刊2020
李圣陶, 龚吉军, 吴敏, 唐静. 基于HiCapt Benzo固相萃取前处理的HPLC-FLD法检测油茶籽油中苯并(a)芘[J]. 食品工业科技, 2016, (08): 77-80. DOI: 10.13386/j.issn1002-0306.2016.08.007
引用本文: 李圣陶, 龚吉军, 吴敏, 唐静. 基于HiCapt Benzo固相萃取前处理的HPLC-FLD法检测油茶籽油中苯并(a)芘[J]. 食品工业科技, 2016, (08): 77-80. DOI: 10.13386/j.issn1002-0306.2016.08.007
LI Sheng-tao, GONG Ji-jun, WU Min, TANG Jing. A detection method over benzo(a) pyrene in Camellia oleifera Abel seed oil by HPLC-FLD based on Hi Capt Benzo solid-phase extraction pretreatment[J]. Science and Technology of Food Industry, 2016, (08): 77-80. DOI: 10.13386/j.issn1002-0306.2016.08.007
Citation: LI Sheng-tao, GONG Ji-jun, WU Min, TANG Jing. A detection method over benzo(a) pyrene in Camellia oleifera Abel seed oil by HPLC-FLD based on Hi Capt Benzo solid-phase extraction pretreatment[J]. Science and Technology of Food Industry, 2016, (08): 77-80. DOI: 10.13386/j.issn1002-0306.2016.08.007

基于HiCapt Benzo固相萃取前处理的HPLC-FLD法检测油茶籽油中苯并(a)芘

A detection method over benzo(a) pyrene in Camellia oleifera Abel seed oil by HPLC-FLD based on Hi Capt Benzo solid-phase extraction pretreatment

  • 摘要: 为了建立一种基于Hi Capt Benzo固相萃取快速前处理的,更灵敏、准确的高效液相色谱-荧光检测法,以用于油茶籽油中苯并(a)芘的检测。油茶籽油样品以正己烷溶解后,用Hi Capt Benzo专用固相萃取柱净化。检测条件为:LC-PAHs专用色谱柱;50%乙腈-50%水为流动相,流速1.0 m L/min;荧光检测器;外标法定量。研究结果表明,苯并(a)芘标准曲线在0.1200 ng/m L范围内,线性关系好(R2=0.9993);检测限很低(0.02130.0246μg/kg)。该法用于4个油茶籽油样品加标检测,回收率为93.06%104.52%,相对标准偏差(RSD)为2.12%3.98%。本文所建固相萃取-高效液相色谱(带荧光检测器)法前处理简单,结果准确可靠,是油茶籽油苯并(a)芘高效检测的适宜方法。 

     

    Abstract: This study was aimed to establish a highly efficient method of high-performance liquid chromatography with fluorescence detection(HPLC-FLD) based on Hi Capt Benzo solid-phase extraction time-saving pretreatment for benzo(a) pyrene B(a)P detection in Camellia oleifera Abel seed oil(COASO). Samples of COASO were dissolved in hexane,and purified by Hi Capt Benzo solid phase extraction(SPE) column. The detection conditions were as followings:LC-PAHs chromatographic column,50% acetonitrile-50% pure water as mobile phase,flow rate 1.0 m L/min,fluorescence detector,quantification by external standard method. The results showed that standard calibration curve was linear over the concentration range of 0.1~200 ng/m L,with the regression efficiency(R2) of 0.9993. Furthermore,the detection limit was 0.0213~0.0246 μg/kg. A recovery range of 93.06%~104.52%and a relative standard deviation(RSD) range of 2.12%~3.98% was exhibited when the method was employed to detect four samples of COASO added with B(a)P standand. It was suggested that this detection method of SPE-HPLC-FLD established in the study was a suitable one for B(a)P detection in COASO,for its obvious advantages,such as simpler pretreatment,more sensitive and more efficient.

     

/

返回文章
返回