刘松,赵振宇,曾稳稳,等. UPLC-Q-Orbitrap HRMS测定白酒接触塑料制品中21种双酚类及其衍生物[J]. 食品工业科技,2021,42(9):263−269. doi: 10.13386/j.issn1002-0306.2020060229.
引用本文: 刘松,赵振宇,曾稳稳,等. UPLC-Q-Orbitrap HRMS测定白酒接触塑料制品中21种双酚类及其衍生物[J]. 食品工业科技,2021,42(9):263−269. doi: 10.13386/j.issn1002-0306.2020060229.
LIU Song, ZHAO Zhenyu, ZENG Wenwen, et al. Simultaneous Determination of 21 Bisphenol and Bisphenol Derivatives in Baijiu Contact Plastic Materials by UPLC-Q-Orbitrap High Resolution Mass Spectrometry[J]. Science and Technology of Food Industry, 2021, 42(9): 263−269. (in Chinese with English abstract). doi: 10.13386/j.issn1002-0306.2020060229.
Citation: LIU Song, ZHAO Zhenyu, ZENG Wenwen, et al. Simultaneous Determination of 21 Bisphenol and Bisphenol Derivatives in Baijiu Contact Plastic Materials by UPLC-Q-Orbitrap High Resolution Mass Spectrometry[J]. Science and Technology of Food Industry, 2021, 42(9): 263−269. (in Chinese with English abstract). doi: 10.13386/j.issn1002-0306.2020060229.

UPLC-Q-Orbitrap HRMS测定白酒接触塑料制品中21种双酚类及其衍生物

Simultaneous Determination of 21 Bisphenol and Bisphenol Derivatives in Baijiu Contact Plastic Materials by UPLC-Q-Orbitrap High Resolution Mass Spectrometry

  • 摘要: 建立了超高效液相色谱/四极杆-静电场轨道阱高分辨质谱法(UPLC-Q-Orbitrap HRMS)测定白酒接触塑料制品中21种双酚类及其衍生物的筛查定量方法。迁移后模拟液用甲醇稀释10倍,采用C18色谱柱,以甲醇−5 mmol/L乙酸铵水溶液为流动相进行梯度洗脱,21种目标物在质量浓度范围2.5~500.0 µg/L范围内线性良好,R2大于0.9965,方法定量限为6.0~36.3 µg /L,回收率为82.3%~106.4%,RSD为0.7%~5.2%之间。该方法种类覆盖广,灵敏度高,准确性好,应用于实际样品检测时重复性良好,可为白酒生产过程中此类化合物的风险监测提供技术支撑。

     

    Abstract: A method was developed for the simultaneous determination of 21 bisphenol and bisphenol derivatives in Baijiu contact plastic materials by ultra high performance liquid chromatography- high resolution mass spectrometry. The simulation solution was diluted 10 times with methanol. The compounds were separated on a C18 chromatographic column with the gradient elution of water (contain 5 mmol/L ammonium) and methanol as mobile phase. The result showed that the limits of quantification were in the range of 2.5~500.0 µg/L, and the correlation coefficients (R2) of 21 target compounds were higher than 0.9965. The average spiked recoveries were in the range of 82.3%~106.4%, and the relative standard deviations (RSD) were in the range of 0.7%~5.2%. This method was simple, rapid, sensitive, accurate, and could be used for the monitoring of 21 bisphenol and bisphenol diglycidyl ethers in Baijiu and Baijiu contact plastic materials

     

/